Note:

The Hybrid 200 unit is mainly controlled through the Humifresh mobile application. For users who prefer not to use the mobile app, an optional Control panel, sold separately and not included with the unit by default, is available upon request. Please contact customer service to place an order.

  1. Control Set-up and Location

The unit is equipped with an AC/DC adapter GST160A24-R7B”. The Hybrid 200 should be powered using the provided AC/DC power supply. If the main service door is closed, the unit will start running immediately. A safety disconnect switch cuts all power to the unit when the main service door is opened or removed.

Once the Hybrid 200 unit has been mounted and powered, the control will need to be paired. To complete the pairing process, the control should be powered next to the Hybrid 200 unit using the provided DC power block. The following steps will allow your control to be paired to your Hybrid 200.

  1. Power the Humifresh control next to Hybrid 200 unit. (Keep the Hybrid 200 Unplugged)
  2. The control will prompt you to unplug your Hybrid 200 unit, once done confirm on control
  3. The control will prompt you to plug your Hybrid 200, once done confirm on control
  4. Control and Hybrid 200 should now be paired, if pairing process did not work, power off both unit and repeat the pairing process

Note: Steps 2 and 3 can take upwards to a minute to complete.   

Once the control is configured and the system has been paired, you must now find a location for the control. The Humifresh control must be located on the main floor and above the Hybrid 200 unit as much as possible while trying to stay away direct sunlight and other sources of heat.  

DO NOT mount the control to the wall until setup is completed.  

The control can either be placed on a flat surface by using the Desk Stand that is provided or can be mounted to the wall if desired. A mounting template is provided to assist in placing the mounting anchors and screws at the appropriate location.

2 USB power ports are located on the Control to allow multiple installation configurations, either one can be used to power the control.    

DO NOT plug 2 separate power supplies in these ports